Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 12.784
Filter
1.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38728526

ABSTRACT

CASE: A 58-year-old woman with medical history of a left total hip arthroplasty performed by the direct anterior (DA) approach 2 years prior presented with left hip pain. She was found to have sustained a transverse Vancouver C periprosthetic femur fracture and an unstable periprosthetic pelvic fracture. CONCLUSIONS: This patient's case represents a previously not reported injury about a total hip arthroplasty-with disruption distal to the femoral implant and proximal to the acetabular implant, with the implant-to-bone interface unaffected. This case may guide future treatment of similar injuries.


Subject(s)
Arthroplasty, Replacement, Hip , Periprosthetic Fractures , Humans , Female , Arthroplasty, Replacement, Hip/adverse effects , Middle Aged , Periprosthetic Fractures/surgery , Periprosthetic Fractures/etiology , Periprosthetic Fractures/diagnostic imaging , Femoral Fractures/surgery , Femoral Fractures/diagnostic imaging , Femoral Fractures/etiology
2.
Int J Mol Sci ; 25(9)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38731944

ABSTRACT

Chronic postsurgical pain (CPSP) following total knee arthroplasty (TKA) and total hip arthroplasty (THA) is a prevalent complication of joint replacement surgery which has the potential to decrease patient satisfaction, increase financial burden, and lead to long-term disability. The identification of risk factors for CPSP following TKA and THA is challenging but essential for targeted preventative therapy. Recent meta-analyses and individual studies highlight associations between elevated state anxiety, depression scores, preoperative pain, diabetes, sleep disturbances, and various other factors with an increased risk of CPSP, with differences observed in prevalence between TKA and THA. While the etiology of CPSP is not fully understood, several factors such as chronic inflammation and preoperative central sensitization have been identified. Other potential mechanisms include genetic factors (e.g., catechol-O-methyltransferase (COMT) and potassium inwardly rectifying channel subfamily J member 6 (KCNJ6) genes), lipid markers, and psychological risk factors (anxiety and depression). With regards to therapeutics and prevention, multimodal pharmacological analgesia, emphasizing nonopioid analgesics like acetaminophen and non-steroidal anti-inflammatory drugs (NSAIDs), has gained prominence over epidural analgesia. Nerve blocks and local infiltrative anesthesia have shown mixed results in preventing CPSP. Ketamine, an N-methyl-D-aspartate (NMDA)-receptor antagonist, exhibits antihyperalgesic properties, but its efficacy in reducing CPSP is inconclusive. Lidocaine, an amide-type local anesthetic, shows tentative positive effects on CPSP. Selective serotonin reuptake inhibitors (SSRIs) and serotonin norepinephrine reuptake inhibitors (SNRIs) have mixed results, while gabapentinoids, like gabapentin and pregabalin, present hopeful data but require further research, especially in the context of TKA and THA, to justify their use for CPSP prevention.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Pain, Postoperative , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Knee/adverse effects , Pain, Postoperative/etiology , Pain, Postoperative/drug therapy , Chronic Pain/etiology , Chronic Pain/drug therapy , Risk Factors , Pain Management/methods , Analgesics/therapeutic use , Analgesics/pharmacology
3.
BMJ Open ; 14(5): e082501, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38719289

ABSTRACT

BACKGROUND: Prosthetic joint infections (PJIs) are a serious negative outcome of arthroplasty with incidence of about 1%. Risk of PJI could depend on local treatment policies and guidelines; no UK-specific risk scoring is currently available. OBJECTIVE: To determine a risk quantification model for the development of PJI using electronic health records. DESIGN: Records in Clinical Practice Research Datalink (CPRD) GOLD and AURUM of patients undergoing hip or knee arthroplasty between January 2007 and December 2014, with linkage to Hospital Episode Statistics and Office of National Statistics, were obtained. Cohorts' characteristics and risk equations through parametric models were developed and compared between the two databases. Pooled cohort risk equations were determined for the UK population and simplified through stepwise selection. RESULTS: After applying the inclusion/exclusion criteria, 174 905 joints (1021 developed PJI) were identified in CPRD AURUM and 48 419 joints (228 developed PJI) in CPRD GOLD. Patients undergoing hip or knee arthroplasty in both databases exhibited different sociodemographic characteristics and medical/drug history. However, the quantification of the impact of such covariates (coefficients of parametric models fitted to the survival curves) on the risk of PJI between the two cohorts was not statistically significant. The log-normal model fitted to the pooled cohorts after stepwise selection had a C-statistic >0.7. CONCLUSIONS: The risk prediction tool developed here could help prevent PJI through identifying modifiable risk factors pre-surgery and identifying the patients most likely to benefit from close monitoring/preventive actions. As derived from the UK population, such tool will help the National Health Service reduce the impact of PJI on its resources and patient lives.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Prosthesis-Related Infections , Humans , Prosthesis-Related Infections/epidemiology , Male , Female , Arthroplasty, Replacement, Knee/adverse effects , United Kingdom/epidemiology , Middle Aged , Retrospective Studies , Aged , Arthroplasty, Replacement, Hip/adverse effects , Risk Factors , Risk Assessment/methods , Databases, Factual , Electronic Health Records , Adult , Aged, 80 and over
4.
Front Cell Infect Microbiol ; 14: 1343338, 2024.
Article in English | MEDLINE | ID: mdl-38746784

ABSTRACT

Objectives: To investigate the efficacy of serum protein electrophoresis (SPE) in the diagnosis of periprosthetic joint infection (PJI) after hip and knee arthroplasty. Methods: The medical records of patients undergoing hip and knee arthroplasty at a class A tertiary hospital between August 2013 and January 2021 were retrospectively investigated. A total of 179 patients were included and divided into two groups: 66 patients in the PJI group and 113 patients in the aseptic loosening (AL) group. Serum C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), D-dimer, Fibrinogen, Serum albumin and the proportion of serum protein in SPE were compared between the two groups. The diagnostic sensitivity and specificity were determined using the receiver operating characteristic (ROC) curve, and the diagnostic value was compared using the area under the ROC curve (AUC). Results: There was no significant difference in age, sex and body mass index (BMI) between PJI group and AL group (P>0.05), but there was significant difference in the ratio of hip to knee (X2 = 22.043, P<0.001). The CRP, ESR, D-dimer, Fibrinogen and the proportion of α1 globulin band in PJI group was 22.99(10.55,40.58) mg/L, 37.00(23.00,61.70) mm/h, 790.00(500.00,1500.00) ng/ml, 4.84(3.81,5.55) g/L and 5.80(5.00,7.73) % which was higher than that in AL group [1.89(0.50,4.12) mg/L, U=7.984, P<0.001; 10.10(7.00,16.90) mm/h, U=8.095, P<0.001; 570.00(372.50,780.00) ng/ml, U=3.448, P<0.001; 2.84(2.45,3.43) g/L, U=8.053, P<0.001 and 4.20(3.90,4.80) %, U=8.154, P<0.001]. The Serum albumin and the proportion of Albumin band in PJI group was 36.10(33.10,39.00) g/L and 49.00(44.95,52.20) % which was lower than that in AL group [38.10(34.00,41.10) g/L, U=-2.383, P=0.017 and 54.40(51.55,56.70) %, U=-6.162, P<0.001]. The proportion of In PJI group, the AUC of proportion of α1 globulin was 0.8654, which was equivalent to CRP (0.8698), ESR (0.8680) and outperformed that of fibrinogen (0.8025). Conclusions: Elevated proportion of α1 globulin in SPE presented with good diagnostic value for Tsukayama type IV PJI, and its accuracy was comparable to those of ESR and CRP. And α1 globulin can assist with CRP and ESR to determining the timing of second-stage revision.


Subject(s)
Arthroplasty, Replacement, Knee , Blood Sedimentation , C-Reactive Protein , Prosthesis-Related Infections , ROC Curve , Humans , Female , Male , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/blood , Aged , Retrospective Studies , Middle Aged , C-Reactive Protein/analysis , Arthroplasty, Replacement, Knee/adverse effects , Blood Proteins/analysis , Arthroplasty, Replacement, Hip/adverse effects , Sensitivity and Specificity , Fibrin Fibrinogen Degradation Products/analysis , Fibrinogen/analysis , Fibrinogen/metabolism , Blood Protein Electrophoresis/methods , Aged, 80 and over
5.
BMC Musculoskelet Disord ; 25(1): 377, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38741113

ABSTRACT

BACKGROUND: Periprosthetic joint infection (PJI) is a severe complication that can occur after total joint arthroplasty (TJA). The timely and accurate diagnosis of PJI is the key to treatment. This study investigated the diagnostic value of platelet to lymphocyte ratio (PLR), platelet count to mean platelet volume ratio (PVR), neutrophil to lymphocyte ratio (NLR) and monocyte to lymphocyte ratio (MLR) in PJI after total knee arthroplasty (TKA) and total hip arthroplasty (THA). METHODS: We performed a retrospective analysis of the patients who underwent revision hip or knee arthroplasty at our Institute between June 2015 and June 2020. Of the 187 patients reviewed, 168 were included in the study. According to the diagnostic criteria of the Musculoskeletal Infection Society (MSIS), 58 patients were in the PJI group, and 110 patients were in the aseptic loosening (AL) group. We recorded and compared the preoperative peripheral blood white blood cell (WBC) count, platelet count (PLT), erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), PLR, PVR, NLR, and MLR in both groups. The diagnostic performance of the WBC, PLT, PLR, PVR, NLR, and MLR individually and in combination with the ESR and CRP for PJI diagnosis was evaluated by receiver operating characteristic (ROC) curves, and the sensitivity, specificity, positive predictive value, and negative predictive value were calculated. RESULTS: Compared to those in the AL group, the mean WBC, PLT, ESR, CRP, PLR, PVR, NLR, and MLR in the peripheral blood of the PJI group were significantly greater (P < 0.05). The analysis of the ROC curve revealed that the ESR, CRP, PLR, PVR, NLR, and MLR in peripheral blood had moderate effectiveness in diagnosing PJI, with area under the curve (AUC) values of 0.760 (95% CI: 0.688-0.823), 0.758 (95% CI: 0.687-0.821), 0.714 (95% CI: 0.639-0.781), 0.709 (95% CI: 0.634-0.777), 0.723 (95% CI: 0.649-0.789), and 0.728 (95% CI: 0.654-0.793), respectively. Conversely, the WBC and PLT counts demonstrated poor diagnostic value for PJI, with AUC values of 0.578 (95% CI: 0.499-0.653) and 0.694 (95% CI: 0.619-0.763), respectively. The results of the prediction model calculations revealed that the combined AUC of the WBC, PLT, ESR, CRP, PLR, PVR, NLR, and MLR was the highest at 0.853 (95% CI, 0.790-0.909), indicating good value in the diagnosis of PJI, with a sensitivity of 82.8% and a specificity of 72.7%. Moreover, the novel composite of parameters improved the accuracy and reliability in diagnosing PJI compared to the traditional biomarkers ESR and CRP (P = 0.015). CONCLUSION: Our study suggested that the diagnostic value of the peripheral blood biomarkers PLR, PVR, NLR, and MLR for diagnosing PJI is limited and not superior to that of the ESR or CRP. However, when the WBC, PLT, ESR, CRP, PLR, PVR, NLR, and MLR are combined, the diagnostic performance of PJI in TJA patients can be improved.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Biomarkers , Prosthesis-Related Infections , Humans , Retrospective Studies , Female , Male , Aged , Middle Aged , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/blood , Prosthesis-Related Infections/etiology , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Biomarkers/blood , Platelet Count , C-Reactive Protein/analysis , Leukocyte Count , Blood Sedimentation , Neutrophils , Lymphocyte Count , Mean Platelet Volume , Aged, 80 and over , Predictive Value of Tests , ROC Curve
6.
Jt Dis Relat Surg ; 35(2): 299-304, 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38727108

ABSTRACT

OBJECTIVES: This study aimed to investigate whether adding tissue samples directly into thioglycolate (TG) broth yielded a greater number of anaerobic organisms than freshly sampled tissue in suspected hip and knee prosthetic joint infections (PJIs). PATIENTS AND METHODS: Between January 2017 and December 2020, a total of 90 patients (46 males, 44 females; median age: 71.7 years; range, 50.8 and 87.8 years) who underwent revision hip or knee arthroplasty were included. Intraoperative samples were taken, with five placed in TG broth and five in standard containers (PC) with subsequent aerobic and anaerobic culturing conducted. Demographic and baseline data of the patients were recorded. The primary outcome was positive bacterial growth from a PJI specimen inoculated directly into TG broth at the time of collection or standard PJI specimen processing. Secondary outcomes investigated were the presence of Cutibacterium acnes (C. acnes) and the curative success of revision procedure. RESULTS: A total of 900 samples (450 PC and 450 TG) were taken from 90 revision arthroplasty patients (47 knees and 43 hips). There was no statistically significant difference in the number of positive bacterial growth samples between TG broth and standard processing (p=0.742). This was consistent with subgroup analysis analyzing C. acnes (p=0.666). CONCLUSION: In hip and knee arthroplasty, there is no benefit in substituting or adding TG broth as a culture medium to better identify both general bacterial species and C. acnes infections specifically. However, the use of TG may be useful in confirming a true positive result for infection.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Prosthesis-Related Infections , Thioglycolates , Humans , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/drug therapy , Female , Male , Aged , Middle Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Thioglycolates/pharmacology , Knee Prosthesis/adverse effects , Knee Prosthesis/microbiology , Culture Media/chemistry , Culture Media/pharmacology , Reoperation , Hip Prosthesis/adverse effects , Hip Prosthesis/microbiology , Specimen Handling/methods , Retrospective Studies
7.
Jt Dis Relat Surg ; 35(2): 433-438, 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38727125

ABSTRACT

Amputation secondary to vascular complications of recurrent dislocations after total hip arthroplasty (THA) is an extremely rare. We describe an unusual case of above-knee amputation resulting from vascular complications after recurrent dislocations of a THA. A 63-year-old male patient with walking pain and limp has a history of acetabular fracture and central dislocation of the femoral head. He was diagnosed as post-traumatic arthritis and subluxation of the femoral head and suffered from four similar dislocations in 210 days after the THA. The patient received conservative treatment after every hip dislocation. However, four months after the fourth reduction, the emergent femoral artery and popliteal artery exploration and catheter thrombectomy were performed at another hospital. An ipsilateral above-knee amputation was done after sepsis and failure of the revascularization procedure. Clinicians should be cognizant that above-knee amputation resulting from vascular complications after recurrent dislocations of a THA may occur. The lack of adherence to critical treatment may have led to the severe outcome of amputation. In conclusion, patient education and compliance are essential for both the treatment of hip dislocations and arterial occlusion. More active and effective measures should be used to prevent such catastrophic events.


Subject(s)
Amputation, Surgical , Arthroplasty, Replacement, Hip , Hip Dislocation , Recurrence , Humans , Male , Middle Aged , Arthroplasty, Replacement, Hip/adverse effects , Hip Dislocation/surgery , Hip Dislocation/etiology , Femoral Artery/surgery
8.
J Orthop Surg (Hong Kong) ; 32(2): 10225536241249591, 2024.
Article in English | MEDLINE | ID: mdl-38706263

ABSTRACT

Deep vein thrombosis (DVT) is one of the common complications after joint replacement, which seriously affects the quality of life of patients. We systematically searched nine databases, a total of eleven studies on prediction models to predict DVT after knee/hip arthroplasty were included, eight prediction models for DVT after knee/hip arthroplasty were chosen and compared. The results of network meta-analysis showed the XGBoost model (SUCRA 100.0%), LASSO (SUCRA 84.8%), ANN (SUCRA 72.1%), SVM (SUCRA 53.0%), ensemble model (SUCRA 40.8%), RF (SUCRA 25.6%), LR (SUCRA 21.8%), GBT (SUCRA 1.1%), and best prediction performance is XGB (SUCRA 100%). Results show that the XGBoost model has the best predictive performance. Our study provides suggestions and directions for future research on the DVT prediction model. In the future, well-designed studies are still needed to validate this model.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Network Meta-Analysis , Postoperative Complications , Venous Thrombosis , Humans , Venous Thrombosis/etiology , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Postoperative Complications/etiology , Postoperative Complications/epidemiology
9.
Lakartidningen ; 1212024 May 08.
Article in Swedish | MEDLINE | ID: mdl-38716590

ABSTRACT

Hip and knee arthroplasties are mostly successful procedures; however, patient injuries may occur and should be reported to Löf, the Swedish patient insurance. This study investigated the incidence of patient injuries after primary total hip and knee arthroplasty in the Swedish regions, differences in incidence depending on annual surgical volume, and types of approved injuries. Approved patient injuries were related to the total number of hip and knee arthroplasties registered in the Swedish Arthroplasty Register 2012-2021. The national incidence was 11.4 and 8.1 per 1,000 hip and knee arthroplasties respectively and varied in the regions from 30.4 to 4.9 and 15.4 to 5.4 per 1,000 hip and knee arthroplasties respectively. Orthopedic departments with higher annual volumes of performed arthroplasties had a lower proportion of patient injuries. Infection was the most common patient injury, followed by nerve lesions and mechanical complications. The differences may be due to underreporting and varying quality of care in the regions. A centralization of hip and knee arthroplasties may be beneficial.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Registries , Humans , Arthroplasty, Replacement, Knee/statistics & numerical data , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/statistics & numerical data , Sweden/epidemiology , Incidence , Postoperative Complications/epidemiology , Female , Male , Orthopedics , Aged
10.
Bull Hosp Jt Dis (2013) ; 82(2): 112-117, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38739658

ABSTRACT

BACKGROUND: The surgical approach used for arthroplasty in the setting of hip fracture has traditionally been decided based on surgeon preference. This study analyzed the ef-fect of the surgical approach on hospital quality measures, complications, and mortality in patients treated with hip arthroplasty for fracture fixation. METHODS: A cohort of consecutive acute hip fracture pa-tients who were 60 years of age or older and who underwent hemiarthroplasty (HA) or total hip arthroplasty (THA) at one academic medical center between January 2014 and January 2018 was included. Patient demographics, length of stay (LOS), surgery details, complications, ambulation at dis-charge, discharge location, readmission, and mortality were recorded. Two cohorts were included based on the surgical approach: the anterior-based cohort included the direct an-terior and anterolateral approaches and the posterior-based cohort included direct lateral and posterior approaches. RESULTS: Two hundred five patients were included: 146 underwent HA (81 anterior-based and 65 posterior-based) and 79 underwent THA (37 anterior-based and 42 posterior-based). The mean age of the HA and THA cohorts was 84.1 ± 7.5 and 73.7 ± 8.0 years, respectively. There was no dif-ference in LOS, time to surgery, or surgical time between the two cohorts for HA and THA. There were no differences in perioperative complications, including dislocation, ob-served based on surgical approach. No difference was found between readmission rates and mortality. CONCLUSION: In this cohort of hip fracture arthroplasty patients, there was no difference observed in hospital quality measures, readmission, or mortality in patients based on sur-gical approach. These results are in contrast with literature in elective arthroplasty patients supporting the use of an anterior approach for potential improved short-term outcomes.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Neck Fractures , Hemiarthroplasty , Length of Stay , Postoperative Complications , Humans , Femoral Neck Fractures/surgery , Femoral Neck Fractures/mortality , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/adverse effects , Female , Aged , Male , Aged, 80 and over , Treatment Outcome , Postoperative Complications/etiology , Length of Stay/statistics & numerical data , Hemiarthroplasty/methods , Hemiarthroplasty/mortality , Hemiarthroplasty/adverse effects , Retrospective Studies , Patient Readmission/statistics & numerical data , Middle Aged
11.
Vet Surg ; 53(4): 620-629, 2024 May.
Article in English | MEDLINE | ID: mdl-38563528

ABSTRACT

OBJECTIVE: To describe the complications and outcomes in dogs with luxoid hip dysplasia (LH) undergoing total hip arthroplasty (THA) and compare complication rates with THA in non-LH dogs. STUDY DESIGN: Retrospective study. SAMPLE POPULATION: Client-owned dogs (n = 217) undergoing primary THA (n = 238). METHODS: Medical records (2010-2022) of dogs undergoing THA were reviewed, and LH was defined as complete dorsal displacement of the femoral head from the acetabulum on lateral projection radiographs. Major or catastrophic complications, revisions, and outcomes were recorded for all dogs and they were compared between LH and non-LH groups. RESULTS: Eighteen cases met the subcriterion for the LH group and 220 cases met the subcriterion for inclusion in the non-LH group. There were 14 complications in 13/18 dogs with LH; seven were intraoperative (femoral fissure/fracture) and seven were postoperative (dorsal luxation, n = 5; femoral fracture, n = 1; acetabular cup septic loosening, n = 1). Revisions were performed for all LH dogs that encountered complications; satisfactory outcomes were achieved in 12/13 dogs. Overall, LH dogs had a higher risk of developing complications (p < .001), including intraoperative fracture (p < .001) and postoperative dorsal luxation (p = .019) when compared with non-LH dogs. CONCLUSION: Luxoid hip dysplasia was associated with a higher risk of major complications following THA in dogs, specifically intraoperative fissure/fracture and postoperative dorsal luxation. Despite the increased risk, revisions typically yielded satisfactory outcomes. CLINICAL SIGNIFICANCE: Luxoid hip dysplasia is an important risk factor for the development of major complications in dogs undergoing THA.


Subject(s)
Arthroplasty, Replacement, Hip , Dog Diseases , Hip Dysplasia, Canine , Postoperative Complications , Dogs , Animals , Arthroplasty, Replacement, Hip/veterinary , Arthroplasty, Replacement, Hip/adverse effects , Retrospective Studies , Hip Dysplasia, Canine/surgery , Male , Postoperative Complications/veterinary , Female , Dog Diseases/surgery , Treatment Outcome
12.
BMJ Open ; 14(4): e076576, 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38684253

ABSTRACT

OBJECTIVES: Prosthetic joint infection (PJI) is a serious complication following total hip arthroplasty (THA) entailing increased mortality, decreased quality of life and high healthcare costs.The primary aim was to investigate whether the national project: Prosthesis Related Infections Shall be Stopped (PRISS) reduced PJI incidence after primary THA; the secondary aim was to evaluate other possible benefits of PRISS, such as shorter time to diagnosis. DESIGN: Cohort study. SETTING: In 2009, a nationwide, multidisciplinary infection control programme was launched in Sweden, PRISS, which aimed to reduce the PJI burden by 50%. PARTICIPANTS: We obtained data on patients undergoing primary THA from the Swedish Arthroplasty Registry 2012-2014, (n=45 723 patients, 49 946 THAs). Using personal identity numbers, this cohort was matched with the Swedish Prescribed Drug Registry. Medical records of patients with ≥4 weeks' antibiotic consumption were reviewed to verify PJI diagnosis (n=2240, 2569 THAs). RESULTS: The cumulative incidence of PJI following the PRISS Project was 1.2% (95% CI 1.1% to 1.3%) as compared with 0.9% (95% CI 0.8% to 1.0%) before. Cox regression models for the PJI incidence post-PRISS indicates there was no statistical significance difference versus pre-PRISS (HR 1.1 (95% CI 0.9 to 1.3)). There was similar time to PJI diagnosis after the PRISS Project 24 vs 23 days (p=0.5). CONCLUSIONS: Despite the comprehensive nationwide PRISS Project, Swedish PJI incidence was higher after the project and time to diagnosis remained unchanged. Factors contributing to PJI, such as increasing obesity, higher American Society of Anesthesiology class and more fractures as indications, explain the PJI increase among primary THA patients.


Subject(s)
Arthroplasty, Replacement, Hip , Infection Control , Prosthesis-Related Infections , Humans , Sweden/epidemiology , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/prevention & control , Prosthesis-Related Infections/etiology , Male , Female , Arthroplasty, Replacement, Hip/adverse effects , Aged , Incidence , Middle Aged , Infection Control/methods , Cohort Studies , Registries , Anti-Bacterial Agents/therapeutic use , Aged, 80 and over
13.
PLoS One ; 19(4): e0300956, 2024.
Article in English | MEDLINE | ID: mdl-38630711

ABSTRACT

Increasing the stem size during surgery is associated with a higher incidence of intraoperative periprosthetic fractures in cementless total hip arthroplasty with fully coated tapered wedge stems, especially in femurs of Dorr type A. If in contrast a stem is implanted and sufficient primary stability is not achieved, such preventing successful osseointegration due to increased micromotions, it may also fail, especially if the stem is undersized. Stem loosening or periprosthetic fractures due to stem subsidence can be the consequence. The adaptation of an established stem design to femurs of Dorr type A by design modifications, which increase the stem width proximally combined with a smaller stem tip and an overall shorter stem, might reduce the risk of distal locking of a proximally inadequately fixed stem and provide increased stability. The aim of this study was to investigate whether such a modified stem design provides improved primary stability without increasing the periprosthetic fracture risk compared to the established stem design. The established (Corail, DePuy Synthes, Warsaw, IN, US) and modified stem designs (Emphasys, DePuy Synthes, Warsaw, IN, US) were implanted in cadaveric femur pairs (n = 6 pairs) using the respective instruments. Broaching and implantation forces were recorded and the contact areas between the prepared cavity and the stem determined. Implanted stems were subjected to two different cyclic loading conditions according to ISO 7206-4 using a material testing machine (1 Hz, 600 cycles @ 80 to 800 N, 600 cycles @ 80 to 1600 N). Translational and rotational relative motions between stem and femur were recorded using digital image correlation. Broaching and implantation forces for the modified stem were up to 40% higher (p = 0.024), achieving a 23% larger contact area between stem and bone (R2 = 0.694, p = 0.039) resulting in a four times lower subsidence during loading (p = 0.028). The slight design modifications showed the desired effect in this in-vitro study resulting in a higher primary stability suggesting a reduced risk of loosening. The higher forces required during the preparation of the cavity with the new broaches and during implantation of the stem could bare an increased risk for intraoperative periprosthetic fractures, which did not occur in this study.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Periprosthetic Fractures , Humans , Hip Prosthesis/adverse effects , Periprosthetic Fractures/epidemiology , Prosthesis Design , Arthroplasty, Replacement, Hip/adverse effects , Osseointegration , Femur/surgery , Reoperation/adverse effects , Retrospective Studies
14.
J Korean Med Sci ; 39(15): e147, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38651227

ABSTRACT

Total joint arthroplasty (TJA) is a surgical procedure, in which parts of damaged joints are removed and replaced with a prosthesis. The main indication of TJA is osteoarthritis, and the volume of TJA is rising annually along with the increase of aged population. Hip and knee are the most common joints, in which TJAs are performed. The TJA prosthesis is composed of metal, plastic, or ceramic device. Even though TJA is the most successful treatment for end-stage osteoarthritis, it is associated with various complications, and periprosthetic joint infection (PJI) is the most serious complication after TJA. With the increasing volume of TJAs, there is a simultaneous rise in the incidence of PJI. Contamination of the surgical wound and the adherence of bacteria to the surface of prosthetic component represent the initial step in the pathogenesis of PJI. The main sources of the contamination are 1) patient's own flora, 2) droplets in the operation room air, and 3) surgical gloves and instruments. Even though modern techniques have markedly reduced the degree of contamination, TJAs cannot be done in completely germ-free conditions and some degree of contamination is inevitable in all surgical procedures. However, not all contamination leads to PJI. It develops when the burden of contamination exceeds the immune threshold or the colony forming units (CFUs) and various factors contribute to a decrease in the CFU level. Surgeons should be aware of the germ burden/CFU concept and should monitor sources of contamination to maintain the germ burden below the CFU to prevent PJI.


Subject(s)
Prosthesis-Related Infections , Humans , Prosthesis-Related Infections/prevention & control , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Anti-Bacterial Agents/therapeutic use
15.
Int J Artif Organs ; 47(4): 290-298, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38584296

ABSTRACT

BACKGROUND: Dislocation is a major complication of total hip arthroplasty (THA). The modular femoral neck system provides practical advantages by allowing adjustment of neck version and length in the presence of intraoperative instability. Anatomical studies have identified morphological differences in the hip joint between men and women. Despite sex-based differences in hip morphology, it remains unclear whether such differences affect neck selectivity in THA using a modular neck system and whether this approach achieves anatomical reconstruction, thereby reducing complications such as dislocation. This study aimed to investigate gender differences in neck selectivity in THA with the modular neck system and assess the clinical impact of the modular neck system. METHODS: A total of 163 THAs using a modular neck system were included in this study. Data on the type of modular neck and intraoperative range of motion (ROM) were retrieved from patient records. Pre- and post-operative leg length differences (LLD) were examined as part of the radiographic assessment. Dislocation was investigated as a postoperative complication. RESULTS: Neck selectivity did not significantly differ between men and women. The comparison of pre- and post-operative LLD revealed a tendency for varus necks to improve LLD more than version-controlled necks. Furthermore, no significant correlation was found between intraoperative ROM and neck selectivity, or postoperative dislocation and neck selectivity. CONCLUSIONS: This study on THA with a modular neck system provided valuable insights into sex-based differences in neck selectivity and highlighted the potential benefits of the modular neck system in addressing LLD and preventing postoperative dislocation.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Prosthesis Design , Range of Motion, Articular , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Female , Male , Aged , Middle Aged , Sex Factors , Femur Neck/surgery , Aged, 80 and over , Hip Joint/surgery , Hip Joint/diagnostic imaging , Hip Joint/physiopathology , Retrospective Studies , Adult , Postoperative Complications/prevention & control , Postoperative Complications/etiology , Treatment Outcome
16.
Zhongguo Zhen Jiu ; 44(4): 395-399, 2024 Apr 12.
Article in English, Chinese | MEDLINE | ID: mdl-38621725

ABSTRACT

OBJECTIVES: To observe the effect of transcutaneous electrical acupoint stimulation (TEAS) on postoperative urinary function in elderly patients undergoing total hip arthroplasty (THA). METHODS: One hundred and eighty elderly patients undergoing unilateral THA without indwelling urinary catheters were randomly assigned to a TEAS group (90 cases, 3 cases dropped out, 4 cases were eliminated) and a sham TEAS group (90 cases, 1 case dropped out, 4 cases were eliminated). Both groups received fascia iliac block and subarachnoid block anesthesia under ultrasound guidance. The patients in the TEAS group were treated with TEAS at Zhongji (CV 3), Guanyuan (CV 4), and bilateral Huiyang (BL 35), Ciliao (BL 32) 30 minutes before anesthesia initiation, with dissperse-dense wave, frequency of 2 Hz/100 Hz, until 30 minutes after surgery. The patients in the sham TEAS group underwent the same procedure with the device applied at the same acupoints but without electrical stimulation. The incidence of postoperative urinary retention (POUR), time to first void, voiding threshold, urinary adenosine triphosphate (ATP) level, postoperative abnormal voiding status (bladder residual volume, re-catheterization rate, nocturia occurrence), and postoperative incidence of urinary tract infection (UTI) and prosthetic joint infection (PJI) were observed in both groups. RESULTS: The incidence of POUR in the TEAS group was lower than that in the sham TEAS group (P<0.05); the time to first void in the TEAS group was shorter than that in the sham TEAS group (P<0.05); the voiding threshold in the TEAS group was lower than that in the sham TEAS group (P<0.05); the urinary ATP level in the TEAS group was higher than that in the sham TEAS group (P<0.05); the bladder residual volume in the TEAS group was lower than that in the sham TEAS group (P<0.05); the nocturia occurrence in the TEAS group was lower than that in the sham TEAS group (P<0.05). However, there was no statistically significant difference in re-catheterization rate, incidence of UTI, and incidence of PJI between the two groups (P>0.05). CONCLUSIONS: TEAS could effectively reduce the occurrence of postoperative urinary retention and improve the postoperative urinary function in elderly patients undergoing THA, which might be related with increasing the urinary ATP level.


Subject(s)
Arthroplasty, Replacement, Hip , Nocturia , Transcutaneous Electric Nerve Stimulation , Urinary Retention , Humans , Aged , Acupuncture Points , Arthroplasty, Replacement, Hip/adverse effects , Transcutaneous Electric Nerve Stimulation/methods , Urinary Retention/etiology , Urinary Retention/therapy , Postoperative Complications/etiology , Postoperative Complications/therapy , Adenosine Triphosphate
18.
Scand J Pain ; 24(1)2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38683162

ABSTRACT

OBJECTIVES: Acute postsurgical pain (APSP) may persist over time and become chronic. Research on predictors for APSP and chronic postsurgical pain (CPSP) has produced inconsistent results. This observational study aimed to analyze psychological and psychophysical variables associated with APSP and CPSP after total knee or hip arthroplasty, and to explore the role of sex. METHODS: Assessments were conducted before surgery, 48 h, and 3 months postsurgery, including questionnaires (sociodemographic, pain related, and psychological) and quantitative sensory testing (QST). Hierarchical linear regression models analyzed potential predictors of APSP and CPSP, and moderation analyses evaluated the role of sex. RESULTS: The study included 63 participants undergoing total knee (34, 54%) or hip (29, 46%) arthroplasty. Thirty-one (49.2%) were female and 32 (50.8%) were male. APSP (48 h) was associated with impaired conditioned pain modulation (CPM) (ß = 0.301, p = 0.019). CPSP (3 months) was associated with being female (ß = 0.282, p = 0.029), longer presurgical pain duration (ß = 0.353, p = 0.006), knee arthroplasty (ß = -0.312, p = 0.015), higher APSP intensity (ß = 373, p = 0.004), and impaired CPM (ß = 0.126, p = 0.004). In multivariate analysis, these clinical variables were significant predictors of CPSP, unlike sex, and CPM (adj. R 2 = 0.349). Moderation analyses showed that wind-up ratio (WUR) was a significant predictor of APSP in men (WUR × sex: b = -1.373, p = 0.046) and CPM was a significant predictor of CPSP in women (CPM × sex: b = 1.625, p = 0.016). CONCLUSIONS: Specific QST parameters could identify patients at risk for high-intensity APSP and CPSP, with sex as a moderator. This has important clinical implications for patient care, paving the way for developing tailored preventive pain management strategies.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Chronic Pain , Pain, Postoperative , Humans , Male , Female , Pain, Postoperative/psychology , Pain, Postoperative/diagnosis , Chronic Pain/psychology , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Aged , Middle Aged , Sex Factors , Acute Pain/psychology , Pain Measurement/methods
19.
Arch Orthop Trauma Surg ; 144(5): 2421-2428, 2024 May.
Article in English | MEDLINE | ID: mdl-38609679

ABSTRACT

BACKGROUND: Femoral stem fracture following total hip arthroplasty (THA) is an infrequent but nevertheless devastating complication, with an increasing worldwide prevalence as demand for primary THA continues to increase. The aim of this study was to perform a systematic review and meta-analysis of risk factors for femoral stem fracture to help identify at risk patients. METHODS: A systematic search was conducted on EMBASE, MEDLINE and AMED to identify relevant studies. Data regarding study design, source, population, intervention, and outcomes was collated. Data extraction was performed on a custom form generated using Cochrane recommended methodology and analysis of risk factors performed including odds ratios (ORs) with 95% confidence intervals (CIs). RESULTS: A total of 15 studies reporting a total of 402 stem fractures in 49 723 THAs were identified. The median time from index procedure to stem fracture was 68 months (IQR 42.5-118) whilst mean age at index surgery was 61.8 years (SD 6.9). Male gender (OR = 3.27, 95% CI = 2.59-4.13, p < 0.001), patient weight above 80 kg (OR = 3.55, 95% CI = 2.88-4.37, p < 0.001), age under 63 years (OR = 1.22, 95% CI = 1.01-1.49, p < 0.001), varus stem alignment (OR = 5.77, 95% CI = 3.83-8.7, p < 0.001), use of modular implants (OR = 1.95, 95% CI = 1.56-2.44, p < 0.01) and undergoing revision arthroplasty (OR = 3.33, 95% CI = 2.70-4.1, p < 0.001) were significant risk factors for prosthetic stem fracture. A risk window of 15 years post-surgery was identified. CONCLUSIONS: This review concludes that patient weight, younger age, male sex, varus stem alignment, revision arthroplasty and use of modular stems are significant risk factors for femoral stem fracture. Modifying these risk factors where possible may help reduce incidence of femoral stem fracture in at risk patients.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Humans , Arthroplasty, Replacement, Hip/adverse effects , Risk Factors , Femoral Fractures/surgery , Femoral Fractures/epidemiology , Femoral Fractures/etiology , Male , Prosthesis Failure , Female , Hip Prosthesis/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Middle Aged
20.
IEEE J Transl Eng Health Med ; 12: 340-347, 2024.
Article in English | MEDLINE | ID: mdl-38606389

ABSTRACT

OBJECTIVE: Cemented total hip arthroplasty (THA) demonstrates superior survival rates compared to uncemented procedures. Nevertheless, most younger patients opt for uncemented THA, as removing well-fixed bone cement in the femur during revisions is complex, particularly the distal cement plug. This removal procedure often increases the risk of femoral fracture or perforation, haemorrhage and weakening bone due to poor drill control and positioning. Aim of this study was to design a novel drill guide to improve drill positioning. METHODS AND PROCEDURES: A novel orthopaedic drill guide was developed, featuring a compliant centralizer activated by a drill guide actuator. Bone models were prepared to assess centralizing performance. Three conditions were tested: drilling without guidance, guided drilling with centralizer activation held, and guided drilling with centralizer activation released. Deviations from the bone centre were measured at the entry and exit point of the drill. RESULTS: In the centralizing performance test, the drill guide significantly reduced drill hole deviations in both entry and exit points compared to the control ([Formula: see text]). The absolute deviation on the exit side of the cement plug was 10.59mm (SD 1.56) for the 'No drill guide' condition, 3.02mm (SD 2.09) for 'Drill guide - hold' and 2.12mm (SD 1.71) for 'Drill guide - release'. The compliant drill guide centralizer significantly lowered the risk of cortical bone perforation during intramedullary canal drilling in the bone models due to better control of the cement drill position. Clinical and Translational Impact Statement: The drill guide potentially reduces perioperative risks in cemented femoral stem revision. Future research should identify optimal scenarios for its application.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Orthopedics , Humans , Arthroplasty, Replacement, Hip/adverse effects , Reoperation , Femur/surgery , Bone Cements/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL
...